Plan 65

In Piping Plan 65A there is an atmospheric leakage collection and detection system for condensing leakage. Failure of the seal will be detected by an excessive flow rate into the leakage collection system. [API 682; G.25]. In Piping Plan 65B there is an atmospheric leakage collection and detection system for condensing leakage. Failure of the seal will be detected by a cumulative leakage into the system. [API 682; G.26]. These systems include a loop that by-passes the orifice to prevent high pressure on the atmospheric side of the seal allowing excessive leakage to be drained.

Standard Features

  • CS vessel material, 1 US gallon (3.8 liters)
  • Level switch
  • CS valves
  • SS tubing and fittings

Options

  • API 682 compliant
  • ASME U or UM stamp, ASME VIII, Div. 1 2015
  • SS valves and vessel
  • All instrument types, ranges, and certifications